Photopic (black) and scotopic (green) luminous efficiency functions.[c 1] The photopic includes the CIE 1931 standard[c 2] (solid), the Judd–Vos 1978 modified data[c 3] (dashed), and the Sharpe, Stockman, Jagla & Jägle 2005 data[c 4] (dotted). The horizontal axis is wavelength in nm.

A luminous efficiency function or luminosity function represents the average spectral sensitivity of human visual perception of light. It is based on subjective judgements of which of a pair of different-colored lights is brighter, to describe relative sensitivity to light of different wavelengths. It is not an absolute reference to any particular individual, but is a standard observer representation of visual sensitivity of theoretical human eye. It is valuable as a baseline for experimental purposes, and in colorimetry. Different luminous efficiency functions apply under different lighting conditions, varying from photopic in brightly lit conditions through mesopic to scotopic under low lighting conditions. When not specified, the luminous efficiency function generally refers to the photopic luminous efficiency function.

The CIE photopic luminous efficiency function y(λ) or V(λ) is a standard function established by the Commission Internationale de l'Éclairage (CIE) and standardized in collaboration with the ISO, [1] and may be used to convert radiant energy into luminous (i.e., visible) energy. It also forms the central color matching function in the CIE 1931 color space.

Details

Fluorescence in beer. The 1 watt, 450 nm laser appears almost as dark as the background despite being overexposed on camera, while the fluorescence produced, between 500 and 600 nm (spanning the most sensitive part of the spectrum), appears much brighter despite being far lower in energy.

There are two luminous efficiency functions in common use. For everyday light levels, the photopic luminosity function best approximates the response of the human eye. For low light levels, the response of the human eye changes, and the scotopic curve applies. The photopic curve is the CIE standard curve used in the CIE 1931 color space.

The luminous flux (or visible power) in a light source is defined by the photopic luminosity function. The following equation calculates the total luminous flux in a source of light:

where

  • Φv is the luminous flux, in lumens;
  • Φe,λ is the spectral radiant flux, in watts per nanometre;
  • y(λ), also known as V(λ), is the luminosity function, dimensionless;
  • λ is the wavelength, in nanometres.

Formally, the integral is the inner product of the luminosity function with the spectral power distribution.[2] In practice, the integral is replaced by a sum over discrete wavelengths for which tabulated values of the luminous efficiency function are available. The CIE distributes standard tables with luminosity function values at 5 nm intervals from 380 nm to 780 nm.[cie 1]

The standard luminous efficiency function is normalized to a peak value of unity at 555 nm (see luminous coefficient). The value of the constant in front of the integral is usually rounded off to 683 lm/W. The small excess fractional value comes from the slight mismatch between the definition of the lumen and the peak of the luminosity function. The lumen is defined to be unity for a radiant energy of 1/683 W at a frequency of 540 THz, which corresponds to a standard air wavelength of 555.016 nm rather than 555 nm, which is the peak of the luminosity curve. The value of y(λ) is 0.999997 at 555.016 nm, so that a value of 683/0.999997 = 683.002 is the multiplicative constant.[3]

The number 683 is connected to the modern (1979) definition of the candela, the unit of luminous intensity.[cie 2] This arbitrary number made the new definition give numbers equivalent to those from the old definition of the candela.

Improvements to the standard

The CIE 1924 photopic V(λ) luminosity function,[cie 3] which is included in the CIE 1931 color-matching functions as the y(λ) function, has long been acknowledged to underestimate the contribution of the blue end of the spectrum to perceived luminance. There have been numerous attempts to improve the standard function, to make it more representative of human vision. Judd in 1951,[4] improved by Vos in 1978,[5] resulted in a function known as CIE VM(λ).[6] More recently, Sharpe, Stockman, Jagla & Jägle (2005) developed a function consistent with the Stockman & Sharpe cone fundamentals;[7] their curves are plotted in the figure above.

ISO standard

The ISO standard is ISO/CIE FDIS 11664-1. The standard provides an incremental table by nm of each value in the visible range.[8][9]

Scotopic luminosity

For very low levels of intensity (scotopic vision), the sensitivity of the eye is mediated by rods, not cones, and shifts toward the violet, peaking around 507 nm for young eyes; the sensitivity is equivalent to 1699 lm/W[10] or 1700 lm/W[11] at this peak.

The standard scotopic luminous efficiency function or V(λ) was adopted by the CIE in 1951, based on measurements by Wald (1945) and by Crawford (1949).[12]

Luminosity for mesopic vision, a wide transitioning band between scotopic and phototic vision, is more poorly standardized. The consensus is that this luminous efficiency can be written as a weighted average of scotopic and mesopic luminosities, but different organizations provide different weighting factors.[13]

Color blindness

Protanopic (red, dotted) and deuteranopic (green, dashed) luminosity functions.[14] For comparison, the standard photopic curve is shown (black, solid).

Color blindness changes the sensitivity of the eye as a function of wavelength. For people with protanopia, the peak of the eye's response is shifted toward the short-wave part of the spectrum (approximately 540 nm), while for people with deuteranopia, there is a slight shift in the peak of the spectrum, to about 560 nm.[14] People with protanopia have essentially no sensitivity to light of wavelengths more than 670 nm.

Most non-primate mammals have the same luminous efficiency function as people with protanopia. Their insensitivity to long-wavelength red light makes it possible to use such illumination while studying the nocturnal life of animals.[15]

For older people with normal color vision, the crystalline lens may become slightly yellow due to cataracts, which moves the maximum of sensitivity to the red part of the spectrum and narrows the range of perceived wavelengths.

See also

References

  1. ISO/CIE 23539:2023 CIE TC 2-93 Photometry — The CIE system of physical photometry. ISO/CIE. 2023. doi:10.25039/IS0.CIE.23539.2023.
  2. Charles A. Poynton (2003). Digital Video and HDTV: Algorithms and Interfaces. Morgan Kaufmann. ISBN 1-55860-792-7.
  3. Wyszecki, Günter & Stiles, W.S. (2000). Color Science - Concepts and Methods, Quantitative Data and Formulae (2nd ed.). Wiley-Interscience. ISBN 0-471-39918-3.
  4. Judd, Deane B. & Wyszecki, Günter (1975). Color in Business, Science and Industry (3rd ed.). John Wiley. ISBN 0-471-45212-2.
  5. Vos, J. J. (1978). "Colorimetric and photometric properties of a 2° fundamental observer". Color Research and Application. 3 (3): 125–128. doi:10.1002/col.5080030309.
  6. Stiles, W. S.; Burch, J. M. (1955). "Interim report to the Commission Internationale de l'Eclairage Zurich 1955, on the National Physical Laboratory's investigation of colour-matching". Optica Acta. 2 (4): 168–181. Bibcode:1955AcOpt...2..168S. doi:10.1080/713821039.
  7. Sharpe, L. T.; Stockman, A.; Jagla, W.; Jägle, H. (2005). "A luminous efficiency function, V*(λ), for daylight adaptation" (PDF). Journal of Vision. 5 (11): 948–968. doi:10.1167/5.11.3. PMID 16441195. Archived from the original (PDF) on April 26, 2012.
  8. "Colorimetry -- Part 1: CIE standard colorimetric observers". Retrieved December 9, 2018.
  9. "Kay & Laby;tables of physical & chemical constants;General physics;SubSection: 2.5.3 Photometry". National Physical Laboratory; UK. Archived from the original on May 1, 2019. Retrieved December 9, 2018.
  10. Kohei Narisada; Duco Schreuder (2004). Light Pollution Handbook. Springer. ISBN 1-4020-2665-X.
  11. Casimer DeCusatis (1998). Handbook of Applied Photometry. Springer. ISBN 1-56396-416-3.
  12. "Scotopic luminosity function".
  13. Photopic and Scotopic lumens - 4: When the photopic lumen fails us
  14. 1 2 Judd, Deane B. (1979). Contributions to Color Science. Washington D.C. 20234: NBS. p. 316.{{cite book}}: CS1 maint: location (link)
  15. I. S. McLennan & J. Taylor-Jeffs (2004). "The use of sodium lamps to brightly illuminate mouse houses during their dark phases" (PDF). Laboratory Animals. 38 (4): 384–392. doi:10.1258/0023677041958927. PMID 15479553. S2CID 710605.

CIE documents

  1. "CIE Selected Colorimetric Tables". Archived from the original on 2017-01-31.
  2. 16th Conférence générale des poids et mesures Resolution 3, CR, 100 (1979), and Metrologia, 16, 56 (1980).
  3. CIE (1926). Commission internationale de l'Eclairage proceedings, 1924. Cambridge University Press, Cambridge.

Curve data

This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.